<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>The Pipe Supports Blog &#187; Clamp</title>
	<atom:link href="http://www.pipingtech.com/blog/tag/clamp/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.pipingtech.com/blog</link>
	<description>View standard and custom designed pipe supports from our past projects. Look at up-close pictures of variable spring hangers, constants and big ton springs. Read the project details, including specifications for a wide range of engineered products and services for various industries and applications.</description>
	<lastBuildDate>Tue, 22 May 2012 22:03:02 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>42” Hold Down with Wedge Support</title>
		<link>http://www.pipingtech.com/blog/2003/10/03/42%e2%80%9d-hold-down-with-wedge-support/</link>
		<comments>http://www.pipingtech.com/blog/2003/10/03/42%e2%80%9d-hold-down-with-wedge-support/#comments</comments>
		<pubDate>Fri, 03 Oct 2003 21:16:33 +0000</pubDate>
		<dc:creator>sylvibarra</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Hold Down Clamps]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1218</guid>
		<description><![CDATA[  PT&#38;P designed and fabricated a Hold Down with wedge support for a 42” pipe. The entire assembly is PTFE, 25% glass filled, bonded and will be used to control and reduce pipe vibration at an LNG plant. Both the Hold Down and wedge support are made from A36 Carbon Steel and a fabric pad [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"> </p>
<div class="wp-caption aligncenter" style="width: 508px"><a href="http://www.flickr.com/photos/pipesupports/4685827113/"><img class="   " title="42” Hold Down with Wedge Support" src="http://farm2.static.flickr.com/1308/4685827113_1bb5487bc2_b.jpg" alt="42” Hold Down with Wedge Support" width="498" height="494" /></a><p class="wp-caption-text">42” Hold Down with Wedge Support</p></div>
<p>PT&amp;P designed and fabricated a <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/holddown/hd1.htm">Hold Down</a> with wedge support for a 42” pipe. The entire assembly is <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/slideplate/ptfe.htm">PTFE, 25% glass filled</a>, bonded and will be used to control and reduce pipe vibration at an LNG plant. Both the Hold Down and wedge support are made from A36 Carbon Steel and a fabric pad which is exceptionally suited for vibration impact and declination.</p>
<p>Want to learn more about hold down clamps? View a past pipe clamp webinar now!<br />
<span id="hs-cta-wrapper-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-wrapper"><br />
<!--HubSpot Call-to-Action Code --><br />
<span id="hs-cta-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-node hs-cta-04c392c8-0a70-4623-81b3-5358351e6823"><br />
<a href="http://www.pipingtech.com/news/webinars/webinar_archives.html?utm_source=Hubspot"><img id="hs-cta-img-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-img" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5dfeafd6-b82c-4439-b2c9-31e3aed3b821-1326381937534/access-our-webinar-archives.png?v=1326381937.89" alt="access-our-webinar-archives" /></a><br />
</span><br />
<script type="text/javascript">// <![CDATA[
(function(){
  var hsjs = document.createElement("script");
     hsjs.type = "text/javascript";
     hsjs.async = true;
     hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=04c392c8-0a70-4623-81b3-5358351e6823";
  (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);
  setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="hidden"}, 1);
  setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="visible"}, 2000);
})();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2003/10/03/42%e2%80%9d-hold-down-with-wedge-support/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Straps for a Chemical Plant in Texas</title>
		<link>http://www.pipingtech.com/blog/2002/11/22/straps-for-a-chemical-plant-in-texas/</link>
		<comments>http://www.pipingtech.com/blog/2002/11/22/straps-for-a-chemical-plant-in-texas/#comments</comments>
		<pubDate>Fri, 22 Nov 2002 20:38:38 +0000</pubDate>
		<dc:creator>justino</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1178</guid>
		<description><![CDATA[Piping Technology &#38; Products, Inc. recently designed and manufactured two strap assemblies for a chemical plant in Texas. These 24&#8242; x 8 straps are comprised of A516-70 plates, struts, pipe clamps, SCHXS and SCH160 pipe, and fabricated turnbuckles. This job was completed within two weeks to meet the customer&#8217;s quick turnaround requirements. Do you require [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 360px"><a href="http://www.flickr.com/photos/pipesupports/4685578047/"><img title="Straps for a Chemical Plant in Texas" src="http://farm5.static.flickr.com/4044/4685578047_be0b86bea9_o.jpg" alt="Straps for a Chemical Plant in Texas" width="350" height="242" /></a><p class="wp-caption-text">Straps for a Chemical Plant in Texas</p></div>
<p>Piping Technology &amp; Products, Inc. recently designed and manufactured two strap assemblies for a chemical plant in Texas.</p>
<p>These 24&#8242; x 8 straps are comprised of A516-70 plates, struts, pipe <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">clamps</a>, SCHXS and SCH160 pipe, and fabricated turnbuckles. This job was completed within two weeks to meet the customer&#8217;s quick turnaround requirements.</p>
<p>Do you require pipe straps in your piping system? Get pricing today!  ﻿<br />
<span id="hs-cta-wrapper-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"><span id="hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"><br />
<a href="http://info.pipingtech.com/request-a-price-quotation"><img id="hs-cta-img-a496eee8-9617-41b9-8091-893dbfaaeb33" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5bdc2c2a-c2d4-4d99-ad57-e3b9aa9034c4-1328563965070/request-a-quote.png?v=1328563965.36" alt="request-a-quote" /></a><br />
</span><script type="text/javascript">// <![CDATA[
   (function(){   var hsjs = document.createElement("script");      hsjs.type = "text/javascript";      hsjs.async = true;      hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=a496eee8-9617-41b9-8091-893dbfaaeb33";   (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="hidden"}, 1);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="visible"}, 2000); })();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2002/11/22/straps-for-a-chemical-plant-in-texas/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>40 Clamp Attachments for a Petrochemical Plant</title>
		<link>http://www.pipingtech.com/blog/2002/05/10/40-clamp-attachments-for-a-petrochemical-plant/</link>
		<comments>http://www.pipingtech.com/blog/2002/05/10/40-clamp-attachments-for-a-petrochemical-plant/#comments</comments>
		<pubDate>Fri, 10 May 2002 19:43:09 +0000</pubDate>
		<dc:creator>Ray</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1180</guid>
		<description><![CDATA[The clamp attachments shown are used for supporting vertical pipe sections to vessel clip anchors. These braces are designed for a maximum horizontal moment of 15,000 ft-lb at the vessel clip. All the clamps provided were made of carbon steel with a hot-dip-galvanized finish. The pipe hanger assembly lengths were fabricated per specifications provided by [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 368px"><a href="http://www.flickr.com/photos/pipesupports/4685586001/"><img title="40 Clamp Attachments for a Petrochemical Plant" src="http://farm5.static.flickr.com/4021/4685586001_d60e7a29ba_o.jpg" alt="40 Clamp Attachments for a Petrochemical Plant" width="358" height="269" /></a><p class="wp-caption-text">40 Clamp Attachments for a Petrochemical Plant</p></div>
<p>The <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">clamp</a> attachments shown are used for supporting vertical pipe sections to vessel clip anchors. These braces are designed for a maximum horizontal moment of 15,000 ft-lb at the vessel clip. All the clamps provided were made of carbon steel with a hot-dip-galvanized finish. The pipe hanger assembly lengths were fabricated per specifications provided by the client.</p>
<p>The clamp components were designed and fabricated for non-standard pipe diameters (i.e. 13-3/4&#8243;, 16-1/2&#8243;) so that they could be used on insulated or finned pipelines.</p>
<p>Are you in need of clamp attachments? Request a quote today and receive a response within 48 hours!<br />
<span id="hs-cta-wrapper-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"> <span id="hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"><br />
<a href="http://info.pipingtech.com/request-a-price-quotation"><img id="hs-cta-img-a496eee8-9617-41b9-8091-893dbfaaeb33" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5bdc2c2a-c2d4-4d99-ad57-e3b9aa9034c4-1328563965070/request-a-quote.png?v=1328563965.36" alt="request-a-quote" /></a><br />
</span> <script type="text/javascript">// <![CDATA[
   (function(){   var hsjs = document.createElement("script");      hsjs.type = "text/javascript";      hsjs.async = true;      hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=a496eee8-9617-41b9-8091-893dbfaaeb33";   (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="hidden"}, 1);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="visible"}, 2000); })();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2002/05/10/40-clamp-attachments-for-a-petrochemical-plant/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>24&quot;, Chrome-Moly, Three-Bolt Clamps with Stanchions</title>
		<link>http://www.pipingtech.com/blog/2002/04/05/24-chrome-moly-three-bolt-clamps-with-stanchions/</link>
		<comments>http://www.pipingtech.com/blog/2002/04/05/24-chrome-moly-three-bolt-clamps-with-stanchions/#comments</comments>
		<pubDate>Fri, 05 Apr 2002 20:52:28 +0000</pubDate>
		<dc:creator>sylvibarra</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>
		<category><![CDATA[Three-Bolt Clamps]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1182</guid>
		<description><![CDATA[Piping Technology &#38; Products, Inc. designed and fabricated 24&#8243;, chrome-moly, three-bolt clamps with horizontal guide stanchions for a 765 MW natural gas-fired combined cycle facility in Mexico. These clamps, in conjunction with variable springs, will allow for vertical and axial pipe movement while restricting lateral movements. They were made for 24&#8243; OD pipe from 1-1/2 [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 310px"><a href="http://www.flickr.com/photos/pipesupports/4686237126/"><img title="24&quot;, Chrome-Moly, Three-Bolt Clamps with Stanchions" src="http://farm2.static.flickr.com/1280/4686237126_018eb851ca_o.jpg" alt="24&quot;, Chrome-Moly, Three-Bolt Clamps with Stanchions" width="300" height="225" /></a><p class="wp-caption-text">24&quot;, Chrome-Moly, Three-Bolt Clamps with Stanchions</p></div>
<p>Piping Technology &amp; Products, Inc. designed and fabricated 24&#8243;, chrome-moly, <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">three-bolt clamps </a>with horizontal guide stanchions for a 765 MW natural gas-fired combined cycle facility in Mexico.</p>
<p>These clamps, in conjunction with <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/spring/variable/index.html">variable springs</a>, will allow for vertical and axial pipe movement while restricting lateral movements. They were made for 24&#8243; OD pipe from 1-1/2 x 9&#8243; stock material. Based upon design considerations, the clamp &#8220;E&#8221; dimension, from pipe centerline to outer load bolt, was 25&#8243;. The clamps were designed for operation at 1065°F and per customer-supplied information, the vertical design load was 1,848 lbs and the maximum lateral load was 19,207 lbs.</p>
<p>The clamp plates are made of A387 GR. 22 plate material, stanchion pieces of A335 GR.22 pipe and the side stop plates of carbon steel.</p>
<p>Want more information on three-bolt clamps? Learn more about them in our webinar archives!</p>
<p style="text-align: center;"><span id="hs-cta-wrapper-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-wrapper"><br />
<!--HubSpot Call-to-Action Code --><br />
<span id="hs-cta-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-node hs-cta-04c392c8-0a70-4623-81b3-5358351e6823"><br />
<a href="http://www.pipingtech.com/news/webinars/webinar_archives.html?utm_source=Hubspot"><img id="hs-cta-img-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5dfeafd6-b82c-4439-b2c9-31e3aed3b821-1326381937534/access-our-webinar-archives.png?v=1326381937.89" alt="access-our-webinar-archives" /></a><br />
</span><br />
<script type="text/javascript">// <![CDATA[
 (function(){   var hsjs = document.createElement("script");      hsjs.type = "text/javascript";      hsjs.async = true;      hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=04c392c8-0a70-4623-81b3-5358351e6823";   (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);   setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="hidden"}, 1);   setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="visible"}, 2000); })();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2002/04/05/24-chrome-moly-three-bolt-clamps-with-stanchions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>66&quot; Diameter, Three-bolt Pipe Clamp</title>
		<link>http://www.pipingtech.com/blog/2002/02/08/66-diameter-three-bolt-pipe-clamp/</link>
		<comments>http://www.pipingtech.com/blog/2002/02/08/66-diameter-three-bolt-pipe-clamp/#comments</comments>
		<pubDate>Fri, 08 Feb 2002 20:55:24 +0000</pubDate>
		<dc:creator>rakesh</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>
		<category><![CDATA[Three-Bolt Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1185</guid>
		<description><![CDATA[Piping Technology &#38; Products, Inc. custom designed and fabricated a 66-inch diameter, three-bolt pipe clamp for a chemical company located in Deer Park, Texas. The clamp will be used in conjunction with a PT&#38;P Spring Hanger and a length of rod in order to support the pipeline.  After formation, the clamp&#8217;s dimensions measured at 97.75 [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 292px"><a href="http://www.flickr.com/photos/pipesupports/4686250572/"><img title="66&quot; Diameter, Three-bolt Pipe Clamp" src="http://farm5.static.flickr.com/4054/4686250572_6341a301ef_o.jpg" alt="66&quot; Diameter, Three-bolt Pipe Clamp" width="282" height="351" /></a><p class="wp-caption-text">66&quot; Diameter, Three-bolt Pipe Clamp</p></div>
<div class="wp-caption alignleft" style="width: 246px"><a href="http://www.flickr.com/photos/pipesupports/5185355515/"><img class=" " title="66&quot; Diameter, Three-bolt Pipe Clamp" src="http://farm2.static.flickr.com/1030/5185355515_a3b7be6c49.jpg" alt="66&quot; Diameter, Three-bolt Pipe Clamp" width="236" height="210" /></a><p class="wp-caption-text">66&quot; Diameter, Three-bolt Pipe Clamp</p></div>
<p>Piping Technology &amp; Products, Inc. custom designed and fabricated a 66-inch diameter, <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">three-bolt pipe clamp</a> for a chemical company located in Deer Park, Texas.</p>
<p>The clamp will be used in conjunction with a PT&amp;P <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/spring/index.html">Spring Hanger</a> and a length of rod in order to support the pipeline.  After formation, the clamp&#8217;s dimensions measured at 97.75 OAL and 69.5 at its widest point. By using a FEA program, the clamp was designed for an operating load of 24,000 pounds at 500° F. The materials used consisted of 1 ¾ x 10 x 128 ¼ thick A-36 Carbon steel, with three 2½ studs and nuts.</p>
<p>In need of some three-bolt pipe clamps? Request for pricing today!<br />
<span id="hs-cta-wrapper-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"> <span id="hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"><br />
<a href="http://info.pipingtech.com/request-a-price-quotation"><img id="hs-cta-img-a496eee8-9617-41b9-8091-893dbfaaeb33" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5bdc2c2a-c2d4-4d99-ad57-e3b9aa9034c4-1328563965070/request-a-quote.png?v=1328563965.36" alt="request-a-quote" /></a><br />
</span> <script type="text/javascript">// <![CDATA[
   (function(){   var hsjs = document.createElement("script");      hsjs.type = "text/javascript";      hsjs.async = true;      hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=a496eee8-9617-41b9-8091-893dbfaaeb33";   (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="hidden"}, 1);   setTimeout(function() {document.getElementById("hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33").style.visibility="visible"}, 2000); })();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2002/02/08/66-diameter-three-bolt-pipe-clamp/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>40&quot; Diameter, Alloy Yoke Clamp</title>
		<link>http://www.pipingtech.com/blog/2001/10/12/40-diameter-alloy-yoke-clamp/</link>
		<comments>http://www.pipingtech.com/blog/2001/10/12/40-diameter-alloy-yoke-clamp/#comments</comments>
		<pubDate>Fri, 12 Oct 2001 19:59:37 +0000</pubDate>
		<dc:creator>Ray</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>
		<category><![CDATA[Yoke Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1187</guid>
		<description><![CDATA[PT&#38;P specially designed and manufactured a heavy duty, 40-inch diameter, alloy yoke clamp (cut from a 6&#8243; thick plate) for a Power Plant in Mississippi. The clamp was designed for a 70,000 lb load and is to support a 40&#8243; diameter, high pressure main steam line. The u-bolt was made of a 3&#8243; diameter bar. [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 472px"><a href="http://www.flickr.com/photos/pipesupports/4686260612/"><img title="40&quot; Diameter, Alloy Yoke Clamp" src="http://farm5.static.flickr.com/4004/4686260612_f53e4bc681_o.jpg" alt="40&quot; Diameter, Alloy Yoke Clamp" width="462" height="179" /></a><p class="wp-caption-text">40&quot; Diameter, Alloy Yoke Clamp</p></div>
<p>PT&amp;P specially designed and manufactured a heavy duty, 40-inch diameter, alloy yoke <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">clamp </a>(cut from a 6&#8243; thick plate) for a Power Plant in Mississippi. The clamp was designed for a 70,000 lb load and is to support a 40&#8243; diameter, high pressure main steam line. The u-bolt was made of a 3&#8243; diameter bar. In order to prove the design of this clamp, <a rel="nofollow" href="http://www.pipingtech.com/services/stressana.htm">Finite Element Analysis</a> was used to simulate the loads and stresses that it may experience in the field. The model shows the stresses at every point by a color coding system.</p>
<p><span style="text-align: center;">Want to learn more about yoke clamps and other types of clamps? Visit our webinar archives today!</span></p>
<p style="text-align: center;"><span id="hs-cta-wrapper-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-wrapper"> <span id="hs-cta-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-node hs-cta-04c392c8-0a70-4623-81b3-5358351e6823"><br />
<a href="http://www.pipingtech.com/news/webinars/webinar_archives.html?utm_source=Hubspot"><img id="hs-cta-img-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5dfeafd6-b82c-4439-b2c9-31e3aed3b821-1326381937534/access-our-webinar-archives.png?v=1326381937.89" alt="access-our-webinar-archives" /></a><br />
</span><br />
<script type="text/javascript">// <![CDATA[
(function(){
  var hsjs = document.createElement("script");
     hsjs.type = "text/javascript";
     hsjs.async = true;
     hsjs.src = "//cta-service.cms.hubspot.com/cta-service/loader.js?placement_guid=04c392c8-0a70-4623-81b3-5358351e6823";
  (document.getElementsByTagName("head")[0]||document.getElementsByTagName("body")[0]).appendChild(hsjs);
  setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="hidden"}, 1);
  setTimeout(function() {document.getElementById("hs-cta-04c392c8-0a70-4623-81b3-5358351e6823").style.visibility="visible"}, 2000);
})();
// ]]&gt;</script><br />
<!-- HubSpot Call-to-Action Code --><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/2001/10/12/40-diameter-alloy-yoke-clamp/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Arrestor Type Hold Down</title>
		<link>http://www.pipingtech.com/blog/1994/03/09/arrestor-type-hold-down/</link>
		<comments>http://www.pipingtech.com/blog/1994/03/09/arrestor-type-hold-down/#comments</comments>
		<pubDate>Wed, 09 Mar 1994 22:26:12 +0000</pubDate>
		<dc:creator>Ray</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Hold Down Clamps]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1224</guid>
		<description><![CDATA[The above photo shows an arrestor type hold down. This type of restraint is used when there is very low thermal movement. Its radius is lined with a belting material designed to absorb shock from movement. It is widely used on compressor lines or similar applications. The restraint type hold down&#8217;s clamp radius and base [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 514px"><a href="http://www.flickr.com/photos/pipesupports/4685860389/"><img class=" " title="Arrestor Type Hold Down" src="http://farm5.static.flickr.com/4036/4685860389_da52bd848e_b.jpg" alt="Arrestor Type Hold Down" width="504" height="323" /></a><p class="wp-caption-text">Arrestor Type Hold Down</p></div>
<p>The above photo shows an arrestor type <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/holddown/hd3.htm">hold down</a>. This type of restraint is used when there is very low thermal movement. Its radius is lined with a belting material designed to absorb shock from movement. It is widely used on compressor lines or similar applications. The restraint type hold down&#8217;s clamp radius and base is lined with PT&amp;P’s <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/slideplate/ptfe.htm">PTFE slide plate </a>which allows for axial movement while restraining lateral movement and used on compressor lines where temperatures are high and thermal movement is great. This anchor type hold down is utilized on pipelines and require little or no insulation. It is fabricated from carbon steel and can be used in temperatures up to 750oF.</p>
<p>Would you like to learn more about hold down clamps and slide plates? Visit our website archives today!<br />
<span id="hs-cta-wrapper-04c392c8-0a70-4623-81b3-5358351e6823" class="aligncenter"> <span id="hs-cta-04c392c8-0a70-4623-81b3-5358351e6823" class="aligncenter"><br />
<a href="http://www.pipingtech.com/news/webinars/webinar_archives.html?utm_source=Hubspot"><img id="hs-cta-img-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5dfeafd6-b82c-4439-b2c9-31e3aed3b821-1326381937534/access-our-webinar-archives.png?v=1326381937.89" alt="access-our-webinar-archives" /></a></span> <!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/1994/03/09/arrestor-type-hold-down/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Heavy Duty Beam Clamp Assemblies</title>
		<link>http://www.pipingtech.com/blog/1993/06/04/heavy-duty-beam-clamp-assemblies/</link>
		<comments>http://www.pipingtech.com/blog/1993/06/04/heavy-duty-beam-clamp-assemblies/#comments</comments>
		<pubDate>Fri, 04 Jun 1993 20:02:25 +0000</pubDate>
		<dc:creator>John</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Beam Clamp]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1190</guid>
		<description><![CDATA[Manufactured in Houston, Texas by Piping Technology &#38; Products, heavy duty beam clamp assemblies are used for suspension of heavy loads from standard I-beam and wide flange beams with flange widths to 15” and flange thickness to 1.031”. Do you need a heavy duty beam clamp assembly similar to this one? Get pricing today!]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 272px"><a href="http://www.flickr.com/photos/pipesupports/4686269630/"><img title="Heavy Duty Beam Clamp Assemblies" src="http://farm5.static.flickr.com/4048/4686269630_742ba19285_o.jpg" alt="Heavy Duty Beam Clamp Assemblies" width="262" height="350" /></a><p class="wp-caption-text">Heavy Duty Beam Clamp Assemblies</p></div>
<p>Manufactured in Houston, Texas by Piping Technology &amp; Products, <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/beam/fig140.htm">heavy duty beam clamp</a> assemblies are used for suspension of heavy loads from standard I-beam and wide flange beams with flange widths to 15” and flange thickness to 1.031”.</p>
<p>Do you need a heavy duty beam clamp assembly similar to this one? Get pricing today!</p>
<p><span id="hs-cta-wrapper-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"><span id="hs-cta-a496eee8-9617-41b9-8091-893dbfaaeb33" class="aligncenter"> <a href="http://info.pipingtech.com/request-a-price-quotation"><img id="hs-cta-img-a496eee8-9617-41b9-8091-893dbfaaeb33" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5bdc2c2a-c2d4-4d99-ad57-e3b9aa9034c4-1328563965070/request-a-quote.png?v=1328563965.36" alt="request-a-quote" /></a><br />
</span><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/1993/06/04/heavy-duty-beam-clamp-assemblies/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>86” Diameter Clamps</title>
		<link>http://www.pipingtech.com/blog/1992/05/01/86%e2%80%9d-diameter-clamps/</link>
		<comments>http://www.pipingtech.com/blog/1992/05/01/86%e2%80%9d-diameter-clamps/#comments</comments>
		<pubDate>Fri, 01 May 1992 20:04:28 +0000</pubDate>
		<dc:creator>justino</dc:creator>
				<category><![CDATA[Support Assembly Components]]></category>
		<category><![CDATA[Clamp]]></category>
		<category><![CDATA[Pipe Clamp]]></category>

		<guid isPermaLink="false">http://pipesupportsblog.com/?p=1192</guid>
		<description><![CDATA[Specially formed and gusseted 86” diameter clamps are being strapped to their pallets for their journey to Western Canada. PT&#38;P designed and built these specialty clamps of 3” x 16” bar stock for a major producer of oil and gas in Alberta for an application in their process sector. Would you like to learn more [...]]]></description>
			<content:encoded><![CDATA[<div class="wp-caption aligncenter" style="width: 360px"><a href="http://www.flickr.com/photos/pipesupports/4685645005/"><img title="86” Diameter Clamps" src="http://farm5.static.flickr.com/4066/4685645005_ca363fa111_o.jpg" alt="86” Diameter Clamps" width="350" height="241" /></a><p class="wp-caption-text">86” Diameter Clamps</p></div>
<p>Specially formed and gusseted 86” diameter <a rel="nofollow" href="http://www.pipingtech.com/products/ptpcat/support/clamp/index.html">clamps</a> are being strapped to their pallets for their journey to Western Canada.</p>
<p>PT&amp;P designed and built these specialty clamps of 3” x 16” bar stock for a major producer of oil and gas in Alberta for an application in their process sector.</p>
<p>Would you like to learn more about pipe clamps? Check out a recording of a live pipe clamps webinar.<span id="hs-cta-wrapper-04c392c8-0a70-4623-81b3-5358351e6823" class="aligncenter"><span id="hs-cta-04c392c8-0a70-4623-81b3-5358351e6823" class="aligncenter"> <a href="http://www.pipingtech.com/news/webinars/webinar_archives.html?utm_source=Hubspot"><img id="hs-cta-img-04c392c8-0a70-4623-81b3-5358351e6823" class="hs-cta-img aligncenter" style="border-width: 0px;" src="//d1n2i0nchws850.cloudfront.net/portals/88145/5dfeafd6-b82c-4439-b2c9-31e3aed3b821-1326381937534/access-our-webinar-archives.png?v=1326381937.89" alt="access-our-webinar-archives" /></a></span><br />
<!-- hs-cta-wrapper --></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pipingtech.com/blog/1992/05/01/86%e2%80%9d-diameter-clamps/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>