Hot Shoes Homepage > Technical Bulletins > New Design for Hot Shoes
request-a-quote
New Design for High Temperature Supports
[PDF] Version
 

Over 116 hot shoes for various sizes of large bore high energy steam lines failed. This caused the Energy Center to completely shut down due to safety concerns and the potential for pipe and/or equipment failure. The original vendor replaced the supports with the same type of supports, and they failed once again.

Old Shoes that Pipingtech was called into replace.
Old Shoes that Pipingtech was called into replace.
*failed pipe shoes
Old Shoes that Pipingtech was called into replace.
Old Shoes that Pipingtech was called into replace.
*failed pipe shoes

PT&P was called in to survey the site and found that the type of pipe support used was not suited for the service conditions.

Because the elevations of all the piping were fixed, PT&P had to develop a pipe support design that would dissipate heat, in order to protect the PTFE, 25% glass filled slide plates from thermal damage. Natural Draft Air Cooling has several advantages over previous designs:

1. Since the insulation does not carry any mechanical load, it can be chosen solely on the basis of its thermal properties. In particular, cyclic loading, which has caused insulation failure, is not a problem.

2. The support provides effective restraint for all six possible components of loads, X, Y, Z-Rotational and Translational. In particular, axial and Torsional loads are readily accommodated. These represent difficulties for supports which rely on the insulation.

3. It is easily installed in the field and is attached to the pipe with a standard bolted pipe clamp. Thus, there is no field welding.

Diagram of the new shoe
 
Removal of the defective supports and installation of the new shoes.
Removal of the defective supports and installation of the new shoes.
*Removal of the defective supports and installation of the new shoes
  • The line temperatures ranged from 650°F to 1100°F.
  • PT&P performed full EPC services and manufactured all of the supports for this project.
  • Finite Element Analysis was also performed.
FEA of the newly designed hot shoes.
 
Piping Technology & Products, Inc. designed the solution needed for this dilemma and acquired a new patent for a pipe support with two clamps that are similar to the Figure 50 light two bolt pipe clamp.
Restoration of Insulation
Restoration of Insulation
*Restoration of insulation
Steam lines after installation of PT&P's newly designed shoes
Steam lines after installation of PT&P's newly designed shoes
*Steam lines after installation of PT&P's newly designed shoes

 

Mailing: P.O. Box 34506, Houston, TX 77234-4506 Location: 3701 Holmes Road, Houston, TX 77051
Our Subsidiaries: U.S. Bellows: Metallic & Fabric Expansion Joints, Bellows
Sweco Fab: ASME Vessels, Pig Launchers, Spectacle Blinds
 Pipe Shields: Pre-Insulated Pipe Supports, Slides, Guides & Anchors

Fronek Anchor/Darling
: Snubbers, Sway Struts & Sway Braces
Phone: (713) 731-0030 Toll-Free: (800) 787-5914 FAX: (713) 731-8640 info@pipingtech.com

©2017 Piping Technology and Products, Inc. All Rights Reserved. Contact Us | Privacy Policy